Curve-Fit
Curve-Fit5.0
'CurveFit' uses regression analysis by the method of least squares to find best fit for a set of data to a selected equation. The curve-fitting technique used in this app is based on regression analysis by the method of least squares. The free version fits a straight line through a data-set using
安装
Gas-Leak
Gas-Leak5.0
Gas-Leak provides quick and accurate estimates of leak-rates of Natural Gas, Crude Oil or Water from piping and equipment given hole-size (or seal-leak) with given operating pressure and temperature, assuming the leak is to the atmosphere. The Gas-Leak app is provided as a tool for use in an onshor
安装
Line-Fit
Line-Fit3.7
The Line-Fit app uses linear regression to model the relationship between two variables (x and y) by fitting a linear equation to observed data. One variable is considered to be an explanatory (independent) variable, and the other is considered to be a response (dependent) variable. A linear regre
安装
Oil&GasPVT
Oil&GasPVT1.0
Oil&GasPVT calculates physical properties for gases (Natural Gas, Air and Nitrogen) and liquids (Crude Oil, Water, Methanol (MeOH), Mono-ethylene Glycol (MEG), Di-ethylene Glycol (DEG) and Tri-ethylene Glycol (DEG)): Gas properties: - Compressibility factor (Z-factor - gas deviation factor) - Molec
安装
Gas-Water
Gas-Water-
Knowing the water content of natural gases is essential to the design and operation of production, dehydration, and transmission systems. Water may condense in production and gathering systems. This may result in hydrate formation and plugging of flow systems and damage to internals of production
安装
AGA-3 Orifice
AGA-3 Orifice-
AGA-3 Orifice calculates size, flow-rate or pressure drop for gas and liquid flow orifice meters based on the American Gas Association AGA Report No. 3 (AGA-3) (also API Manual of Petroleum Measurement Standards, Chapter 14.3). Orifice Size is calculated from given flowrate and pressure drop, Flowr
安装
ISO-5167
ISO-5167-
ISO-5167 Orifice calculates size, flow-rate or pressure drop for gas and liquid flow orifice meters based on the International Standard Organization's ISO-5167. Orifice Size is calculated from given flow-rate and pressure drop, Flow-rate is calculated from given size and pressure drop and Pressure D
安装
Restrict_Ori
Restrict_Ori-
Restrict-Ori calculates gas and liquid restriction orifice sizes and flowrates based on R. W. Miller's "Flow Measurement Engineering Handbook". For gases this means that sonic velocity (critical flow) exists at the orifice throat, and further decrease in the downstream pressure will not increase t
安装